Target Adaptation for TriCore AGBT High-speed Serial TracePort


The adaptation is valid for the following TRACE32® product

Order No.Probe
LA-3555PowerTrace Serial 4 GigaByte for TriCore AGBT 
LA-3912Preproc. TriCore AGBT HF-Flex 

For both products, the converter is already included.

Converters

Order No.Probe
LA-3556AGBT Trace Adapter for PowerTrace Serial
LA-3829Conv. Samtec40 to Samtec22 TriCore AGBT

Target Connector Type

SAMTEC Part NumberDescription
ASP-137969-01Rugged High Speed Socket 22 pin

Link to SAMTEC

Target Connector Placement

The adaptation uses a 22-pin Samtec connector. Recommendation is to place the even numbered pins at the PCB border side so the flex cable won't be twisted.

Pinout

Debug and Trace Signals

The pinout of the 22-pin Samtec connector optionally includes the debug signals. The target adapters have a 16-pin JTAG connector and a AUTO26 connector where the user can plug the Debug Cable.
Alternatively the Debug Cable can be plugged on a separate debug connector (JTAG, DAP or AUTO) on the target. In this case there is no need to connect the debug signals to the 22-pin Samtec connector.
Omitting the debug signals on the trace connector may improve signal quality.
The debug signals are TCK, TMS, TRST-, TDI, TDO, RESET- and TRIG (user defined).
Please note that VREF is mandatory for a correct operation of the preprocessor.

Keep unused lanes unconnected!

Signal

Pin

 Pin

Signal

    
RXP012VREF
RXN034TCK
GND56TMS
RXP178TDI
RXN1910TDO
GND1112TRST-
RXP21314CLKP
RXN21516CLKN
GND1718TRIG
RXP31920CRCERR
RXN32122RESET-
    
Target connector, top-view, connect the two latch pins to GND