Adaptation for NEXUS AVR32


The embedded tools company
Adaptation for NEXUS AVR32 on MICTOR



 

Adaptation for NEXUS AVR32 on MICTOR


Trace connectors for AVR32

Trace connector for AVR32
Mictor 38-pin                                                                                                                                                                              

Connector Mictor 38-pin (Debug + Trace signals)

Signal

Pin

 Pin

Signal

    
*)12*)
*)34*)
*)56*)
N/C78*)
RSTIN-910EVTI-
TDO1112VTREF
*)1314*)
TCK1516*)
TMS1718*)
TDI1920MDO05
RST-2122MDO04
MDO112324MDO03
*)2526MDO02
*)2728MDO01
*)2930MDO00
N/C3132EVTO-
N/C3334MCKO
*)3536MSEO1-
N/C3738MSEO0-
    
Connect Pin 39,40,41,42 and 43 to GND

Signal recommendations for Mictor 38-pin

  • Pins marked with *)
The AVR32 Nexus debugger and trace is based on the Nexus Autofocus Probe (NAF) technology, which supports a wide range of architectures with up to 16 bit MDO AUX port width.
Most pins of the probe are internally connected, but not used for AVR32 debugging and trace. Therefore all pins marked with *) should not be connected at the target connector!
  • TDI, TDO, TCK, TMS and RST- should be connected directly to the CPU. Don't connect serial resistors or RC combinations to the lines.
  • All trace signals should also be routed straight from CPU to the Mictor connector.
  • Avoid routing the JTAG signals close to the NEXUS signals.
  • VREF is just a sense input and can be connected directly to target VDD, or optional (recommended) with a serial resistor max. 1kOhm.

Target Connector description and layout

Mictor 38-pin





Order No

TE Connectivity part numbers for suitable receptacles (for target)

TE 2-5767004-2 RoHS compliant
TE 2-767004-2
TE 767054-1 (suggested by Motorola)
TE 767061-1
TE 767044-1 : Board-to-Board Type: Coplanar

TE Connectivity

Probe