Target Adaption of Trace Probe "Beyond" with Mictor-38


Products

    Order No.Probe
    LA-3908Preproc. for Beyond AUTOFOCUS II Flex 


Target Connector Type


    Tyco Part NumberDescription
    2-5767004-2Vertical, surface mount, board to board/cable connector, RoHS compliant.
    767054-1Vertical, surface mount, board to board/cable connector.
    767061-1Vertical, surface mount, board to board/cable connector.
    5767044-1Right angle, straddle mount, board to board/cable connector, RoHS compliant.

    Link to Tyco Electronics

Debug Signals

    The pinout of the Mictor connector optionally includes the debug signals which needs to go to the Debug Cable
    (20-pin standard header). The Preprocessors have a 20-pin connector where the user can plug in the Debug Cable.
    Alternatively the Debug Cable can be plugged on a separate 20-pin connector on the target. In this case there is no
    need to connect the debug signals to the Mictor. For better signal quality it is better not to connect them.
    The debug signals are RESET-, TDO, TCK, TMS, TDI, TRST-, VREF-DEBUG.



Beyond Trace pinning (typically used)


    Signal

    Pin

     Pin

    Signal

        
    N/C12N/C
    N/C34N/C
    N/C56CLK (TRACE)
    N/C78N/C
    SRST-910N/C
    TDO1112VREF-TRACE
    N/C1314VREF-DEBUG
    TCK1516DATA0
    TMS1718DATA1
    TDI1920DATA2
    TRST-2122DATA3
    N/C2324DATA4
    N/C2526DATA5
    N/C2728DATA6
    N/C2930DATA7-CHUNK
    N/C3132N/C
    N/C3334N/C
    N/C3536N/C
    N/C3738VALID
        
    Connect Pin 39,40,41,42,43 to GND



TOP

Converter


Beyond Raptor Platform

order no. Description Dimension Picture
LA-3804 Converter Mictor 38 to XILINX XGI





Copyright © 2016 Lauterbach GmbH, Altlaufstr.40, D-85635 Höhenkirchen-Siegertsbrunn, Germany  Impressum
The information presented is intended to give overview information only.
Changes and technical enhancements or modifications can be made without notice. Report Errors
Last generated/modified: 1-Aug-2016