FAQs Archive for State and Performance Analyzer


The embedded tools company

Search FAQs



PDF document ( 98KB / 27-Mar-2022 )


How can I get prestore information?
Ref: 0029

The prestore function of the TRACE32 state analyzers (SA120/HA120/ECC8/ECC32) can be selected by a mouse click to the 'Prestore' botton in the 'Mode' area of the state analyzer status window. The memory size is than automatically half of the maximum trace memory size. Prestore can only be used if only data accesses are traced, e.g. 'Sample.Enable if VARIABLE_1'. After the anyalyzer has recorded the data accesses, the previous opcode fetches can be seen in the trace list window. The list command must be extended using the keywords PADDRESS and PSYMBOL. ( e.g. A.List.PAddress PsYMBOL DEF).




Copyright © 2023 Lauterbach GmbH, Altlaufstr.40, 85635 Höhenkirchen-Siegertsbrunn, Germany   Impressum     Privacy Policy
The information presented is intended to give overview information only.
Changes and technical enhancements or modifications can be made without notice. Report Errors