FAQs for ICE-166


The embedded tools company

Search FAQs



PDF document ( 63KB / 13-Oct-2016 )


TOP

Power-Down Mode

Ref: 0017
The emulation system goes to SYSDOWN if the processor enters power-down mode.

The dual-port access must be set to DENIED and the "SYS.Option TestCloc"' to OFF. The dual-port cannot work if the processor clock is disabled.
   SYS.ACCESS DENIED
   SYS.OPTION TESTCLOCK OFF


TOP

Update C167E2 to C167E3

Ref: 0104
Can I update the C167E2 module to bondout type C167E3?

The module can be update by changing the chip and adding some wires.

TOP

C167 Bondout Errata Sheet (BONDOUT)

Ref: 0023
Which are the bugs in the bondout chip C167E Step BA

The PDF document is on the INFINEON server at
  http://www.infineon.com/products/ICs/34/pdf/16errata/167e/ba10.pdf
or on our server.

TOP

Clock Errors on E2 Bondout (BONDOUT)

Ref: 0068
The emulator reports 5 different mapper error messages after reset

Clock Generator Problem
The chip internal clock oscillator on the E2 bondout has an undefined clock selector setting after reset. Therefore the clock system can fail after power-up. The only turnaround is to switch down the emulator and target system, and restart the booting sequence again.

TOP

Mixed MUX/NOMUX Operation (BONDOUT)

Ref: 0024
Which Setting must be done for Mixed-Operations

If mixed MUX/NOMUX CS programming is used, the emulator bustype must be set to MUX mode.

TOP

Wrong Clock Frequency on E2 Bondout (BONDOUT)

Ref: 0069
The CPU runs at 50% of the selected clock frequency

The E2 Step AB Bondout has an internal divider error. Instead dividing by 2 it divides by 4 on the 0.5 PLL setting.
Turnaround: Use internal VCO and douple the frequency.

TOP

C167 Bondout Errata Sheet (E1)

Ref: 0023
Which are the bugs in the bondout chip C167E Step BA

The PDF document is on the INFINEON server at
  http://www.infineon.com/products/ICs/34/pdf/16errata/167e/ba10.pdf
or on our server.

TOP

Clock Errors on E2 Bondout (E2)

Ref: 0068
The emulator reports 5 different mapper error messages after reset

Clock Generator Problem
The chip internal clock oscillator on the E2 bondout has an undefined clock selector setting after reset. Therefore the clock system can fail after power-up. The only turnaround is to switch down the emulator and target system, and restart the booting sequence again.

TOP

Wrong Clock Frequency on E2 Bondout (E2)

Ref: 0069
The CPU runs at 50% of the selected clock frequency

The E2 Step AB Bondout has an internal divider error. Instead dividing by 2 it divides by 4 on the 0.5 PLL setting.
Turnaround: Use internal VCO and douple the frequency.